KISE Journal of Korean Institute of Surface Engineering 2009;42(5):232-239. Published online: Nov, 30, -0001
DOI : 10.5695/JKISE.2009.42.5.232
This study presented the effect of membrane thickness on hydrogen permeability. Microvoids on the surface of the membrane should not exist for the exact values of hydrogen permeability. Pd-Cu-Ni hydrogen alloy membranes were fabricated by Ni powder sinter
키워드 Hydrogen permeation;Cu Reflow;Palladium alloy membrane;Void free hydrogen membrane;Sputtering deposition;